5. PARAMETERS
No./symbol/
Setting
name
digit
PC37
Set the offset voltage of VC (Analog speed command).
VCO
For example, if CCW rotation or positive direction travel is provided by switching on
ST1 (Forward rotation start) while applying 0 V to VC, set a negative value.
Analog speed
command
When automatic VC offset is used, the automatically offset value is set to this
offset/
parameter. (Refer to section 4.5.4.)
Analog speed
The initial value is provided before shipment by the automatic VC offset function on
limit offset
condition that the voltage between VC and LG is 0 V.
Setting range: -9999 to 9999
Set the offset voltage of VLA (Analog speed limit).
For example, if CCW rotation or positive direction travel is provided by switching on
RS1 (Forward rotation selection) while applying 0 V to VLA, set a negative value.
When automatic VC offset is used, the automatically offset value is set to this
parameter. (Refer to section 4.5.4.)
The initial value is provided before shipment by the automatic VC offset function on
condition that the voltage between VLA and LG is 0 V.
Setting range: -9999 to 9999
PC38
Set the offset voltage of TC (Analog torque command).
TPO
Analog torque
Setting range: -9999 to 9999
command
Set the offset voltage of TLA (Analog torque limit).
offset/
Analog torque
limit offset
Setting range: -9999 to 9999
PC39
Set the offset voltage of MO1 (Analog monitor 1).
MO1
Analog
monitor 1
offset
Setting range: -9999 to 9999
PC40
Set the offset voltage of MO2 (Analog monitor 2).
MO2
Analog
monitor 2
offset
Setting range: -9999 to 9999
PC43
Set an error excessive alarm level.
ERZ
You can change the setting unit with "Error excessive alarm/error excessive warning
level unit selection" in [Pr. PC24].
Error
excessive
Set this per rev. for rotary servo motors and direct drive motors. Setting "0" will be "3
alarm level
rev", and setting over 200 rev will be clamped with 200 rev. Set this per mm for
linear servo motors. Setting "0" will be 100 mm.
Setting range: 0 to 1000
PC44
_ _ _ x For manufacturer setting
*COP9
_ _ x _
Function
_ x _ _
selection C-9
x _ _ _ Load-side encoder cable communication method selection
Select the communication method of the encoder cable to be connected to the CN2L
connector of MR-J4-_A_-RJ.
0: Two-wire type
1: Four-wire type
When using a load-side encoder of A/B/Z-phase differential output method, set "0".
Incorrect setting will trigger [AL. 70] and [AL. 71]. Setting "1" while using a servo
amplifier other than MR-J4-_A_-RJ will trigger [AL. 37].
This digit is not available with MR-J4-03A6(-RJ) servo amplifiers.
Function
5 - 51
Control
Initial
mode
value
[unit]
P
S
T
The value
differs
depending
on the
servo
amplifiers.
[mV]
0
[mV]
0
[mV]
0
[mV]
0
[rev]/
[mm]
0h
0h
0h
0h

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents