11. OPTIONS AND PERIPHERAL EQUIPMENT
(b) 400 V class
(Note 6)
MCCB
3-phase
380 V AC
to
480 V AC
Step-down
transformer
Note 1. Configure a sequence that will shut off main circuit power in the following.
An alarm occurred at FR-CV-H or servo amplifier.
EM1 (Forced stop 1) is enabled.
2. For the servo amplifier, configure a sequence that will switch the servo-on after the FR-CV-H is ready.
3. Configure a sequence that will make a stop with the forced stop input of the servo amplifier if an alarm occurs in the FR-CV-H.
4. When using FR-CV-H, always disconnect wiring between P3 and P4 terminals.
5. Set [Pr. PA04] to "0 0 _ _" to enable EM1 (Forced stop 1).
6. When wires used for L11 and L21 are thinner than wires used for L1, L2, and L3, use a molded-case circuit breaker.
7. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they
can be configured by one.
FR-CVL-H
MC
R/L11
R2/L12
S/L21
S2/L22
T/L31
T2/L32
(Note 1)
RA1
RA2 EM1 OFF
ON
MC
MC
SK
FR-CV-H
R2/L1
S2/L2
T2/L3
P/L+
N/L-
24 V DC (Note 7)
R/L11
S/L21
P24
T/MC1
SD
RDYB
(Note 2)
RA3
RDYA
A
(Note 1)
RA1
B
RA3 (Note 2)
C
RA1 (Note 3)
24 V DC (Note 7)
11 - 46
Servo amplifier
U
L11
L21
V
W
CN2
P4
(Note 4)
N-
24 V DC (Note 7)
DOCOM
ALM
SON
SON
EM1
EM1 (Note 1, 5)
DICOM
Servo motor
U
V
W
(Note 1)
RA2