Mitsubishi Electric MR-J4-10A(-RJ) Instruction Manual page 749

General-purpose ac servo melservo-j4 general-purpose interface mr-j4 series servo amplifier
Hide thumbs Also See for MR-J4-10A(-RJ):
Table of Contents

Advertisement

18. MR-J4-03A6(-RJ) SERVO AMPLIFIER
(c) Parameters of 7 or more decimal digits
The following example gives the operation procedure to change the [Pr. PA06 Electronic gear
numerator (command pulse multiplication numerator)] to "12345678".
Press "MODE" to switch to the basic setting parameter screen.
Upper 3 digit
......
Change the setting with the
"UP" or "DOWN" button.
......
Note 1. Pressing the "SET" button in upper, middle, or lower 3-digit display makes the display blink.
2. Pressing the "SET" button in upper, middle, or lower 3-digit display fix the setting.
The display can be switched among upper, middle, and lower 3-digits by pressing the "MODE"
button.
Switching the display between upper, middle, and lower 3-digit is also possible by pressing the
"MODE" button while the display is blinking.
The changed value will be canceled when "MODE" is pressed for 2 s or more while blinking.
To shift to the next parameter number, press the "UP" or "DOWN" button.
To change the screen to the other, press "UP" or "DOWN" to change the screen to other parameter
number display screen and press "MODE".
Press "SET" once.
Press "MODE" once.
Press "SET" once.
The display blinks
......
(Note 1)
Press "SET" once.
Enter the setting.
...
(Note 2)
Press "MODE" once.
Press "MODE" once.
Middle 3 digits
Press "SET" once.
......
The display blinks
(Note 1)
Change the setting with the
"UP" or "DOWN" button.
Press "SET" once.
......
Enter the setting.
(Note 2)
18 - 66
Lower 3 digits
......
...

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents