3. Displays the time of dispatch under Time Dispatched
4. Monitors the component continuously to verify whether its performance is within or beyond the set
threshold level

Alarm History screen details

The following are the column headings under which alarms history records are displayed.
Table 11: Alarms History Filters
Screen elements
Metric
Error Status
Arrays
Description
Displays a list of metrics for which components are selected
and alarms configured on them. If you have used the first level
of filters, the Metric list displays only those metrics for which
alarms are created on the selected components.
In addition, the All option lists all the alarms history records that
are created on the different components in the selected XP or
XP7 disk array.
Displays a list of types of error such as:
Email errors
SNMP errors
Script errors
All errors
No errors
Select one of the above-mentioned error types to filter records
and view the status of the respective alarm and SNMP
notifications, and script executions. If you select Email errors,
SNMP errors, Script errors, or All errors, PA returns anything
that is non-zero for these selections. If you select No errors,
PA displays only zero items, that is the alarms that were
successfully dispatched.
Displays the disk arrays for which alarms are generated.