Set The Severity Level For Events - HPE XP7 User Manual

Storage, performance advisor software 7.1
Hide thumbs Also See for XP7:
Table of Contents

Advertisement

Setting the...
Severity level for events
Time zone for management station
Duration to predict the LDEV
response time

Set the severity level for events

Procedure
1. From the HPE XP7 Performance Advisor main menu, click PA Settings > User Settings.
2. Click Edit.
3. From the Log all events with severity at drop-down list in the Event Log section, set the desired
severity level. The options are All, User Action, System Error, and Critical Error.
For example, if you select the severity level as User Action, only messages with that severity level
appear in the Event Log screen.
4. Click Save.
After this setting is saved, the events generated are filtered and only those matching the specified
severity level are displayed on the Event Log screen.
NOTE: This change affects only those messages that are created after you instigated the severity
change. All messages that were logged before you set the severity level still remain in the PA
database, and appear on the Event Log screen.
118
Set the severity level for events
Description
Provides the option to set the severity level for the events that
are logged in the Event log screen. Only those events that match
the specified severity level are displayed on the Event Log
screen. The following are the three types of severity levels:
Severity level
User Action
System Error
Critical Error
Displays the option to choose the time zone for your
management station. This ensures that the management station
is synchronized with the time zone where it resides.
Displays the option to set the duration that PA must use to
predict the average read and write response time of LDEVs.
Description
Errors for user-instigated activities, like
if the user deletes a performance data
collection schedule.
Exception errors given by PA.
Critical errors, where PA may not
function.

Advertisement

Table of Contents
loading

Table of Contents