AR Area
Level 0
Level 1
AR 08
AR 12
AR 09
AR 13
AR 10
AR 14
AR 11
AR 15
*Communication Controller Error Flag
**EEPROM Error Flag
3-5-5
SYSMAC LINK/SYSMAC NET Link System Service Time
(CPU11-E only)
3-5-6

Calendar/Clock Area and Bits (CPU11-E Only)

Calendar/Clock Area
Bits
AR 1800 to AR 1807
Seconds
AR 1808 to AR 1815
Minutes
AR 1900 to AR 1907
Hours
AR 1908 to AR 1915
Day of month
AR 2000 to AR 2007
Month
AR 2008 to AR 2015
Year
AR 2100 to AR 2107
Day of week
Seconds Round-off Bit
Stop Bit
Set Bit
Bit (body of table shows node numbers)
00
01
02
03
04
1
2
3
4
5
17
18
19
20
21
33
34
35
36
37
49
50
51
52
53
AR 16 provides the time allocated to servicing operating level 0 of the SYS-
MAC LINK System and/or SYSMAC NET Link System during each cycle
when a SYSMAC LINK Unit and/or SYSMAC NET Link Unit is mounted to a
Rack.
AR 17 provides the time allocated to servicing operating level 1 of the SYS-
MAC LINK System and/or SYSMAC NET Link System during each cycle
when a SYSMAC LINK Unit and/or SYSMAC NET Link Unit is mounted to a
Rack.
These times are recorded in 4-digit BCD to tenths of a millisecond (000.0 ms
to 999.9 ms) and are refreshed every cycle.
15 to 12
11 to 08
2
1
10
10
If AR 2114 (Stop Bit) is OFF, then the date, day, and time will be available in
BCD in AR 18 to AR 20 and AR 2100 to AR 2108 as shown below. This area
can also be controlled with AR 2113 (Seconds Round-off Bit) and AR 2115
(Set Bit).
Contents
00 to 59
00 to 59
00 to 23 (24-hour system)
01 to 31 (adjusted by month and for leap year)
1 to 12
00 to 99 (Rightmost two digits of year)
00 to 06 (00: Sunday; 01: Monday; 02: Tuesday; 03: Wednesday; 04:
Thursday; 05: Friday; 06: Saturday)
AR 2113 is turned ON to round the seconds of the Calendar/clock Area to
zero, i.e., if the seconds is 29 or less, it is merely set to 00; if the seconds is
30 or greater, the minutes is incremented by 1 and the seconds is set to 00.
AR 2114 is turned OFF to enable the operation of the Calendar/clock Area
and ON to stop the operation.
AR 2115 is used to set the Calendar/clock Area as described below. This
data must be in BCD and must be set within the limits for the Calendar/clock
Area given above.
05
06
07
08
09
6
7
8
9
10
22
23
24
25
26
38
39
40
41
42
54
55
56
57
58
Bits
07 to 04
03 to 00
0
–1
10
10
Possible values
Section 3-5
10
11
12
13
14
11
12
13
14
15
27
28
29
30
31
43
44
45
46
47
59
60
61
62
*
15
16
32
48
**
35