Mitsubishi Electric QD75P1N User Manual page 829

Type qd75p/qd75d positioning module
Table of Contents

Advertisement

APPENDICES
Setting item
Parameter
Cd.2
initialization request
[4]
Parameter initialization method
(1) Parameter initialization is carried out using the dedicated instruction
"ZP.PINIT".
(Refer to CHAPTER 14 "DEDICATED INSTRUCTIONS" for details.)
(2) Parameter initialization can also be carried out by the writing of the data
shown in the table below to the buffer memory using the TO instruction
/intelligent function device.
The initialization of the parameter is executed at the time point the data is
written to the QD75 buffer memory.
Setting
value
1
Set "1" (parameter initialization request).
Refer to Section 5.7 "List of control data" for details on the setting details.
When the initialization is complete, "0" will be set in " Cd.2 Parameter
initialization request" by the QD75 automatically.
Setting details
Appendix - 113
MELSEC-Q
Buffer memory address
Axis
Axis
Axis
Axis
1
2
3
4
1901