14
DEDICATED INSTRUCTIONS
[Control data]
Device
Item
(S)+0
System area
(S)+1
Complete status
Teaching data
(S)+2
selection
(S)+3
Positioning data No.
1: The data on the setting side is as follows.
• User
: Data before the execution of dedicated instructions is stored by user.
• System
: Data after the execution of dedicated instruction is stored by CPU module.
2: Refer to Section 15.3 for error codes at abnormal completion.
[Functions]
The state at the time of completion is stored.
0
Other than 0 : Abnormal completion (error code)( 2)
The address (positioning address/arc address) to which
the current feed value is written is set.
0: Current feed value is written to positioning address.
1: Current feed value is written to arc address.
The positioning data No. for which teaching is carried out
is set.
(1) The "current feed value" of the axes to be set (See below) is set in the positioning
address or arc address.
The positioning data other than the positioning addresses and arc addresses are
set by peripheral device or using a sequence program.
• ZP.TEACH1: Axis 1
• ZP.TEACH2: Axis 2
• ZP.TEACH3: Axis 3
• ZP.TEACH4: Axis 4
(2) Teaching can be carried out for the positioning data No. 1 to 600.
(3) The movement of the machine to the address (position) set in the positioning
address/arc address of the positioning data is carried out by the JOG operation,
inching operation, or manual pulse generator operation.
(4) The ZP.TEACH
devices ((D)+0) and ((D)+1).
(a) Complete device ((D)+0)
This device is turned ON by the END processing of the scan for which
ZP.TEACH
processing.
(b) Complete state display device ((D)+1)
This device is turned ON and OFF according to the state in which
ZP.TEACH
• When completed normally
• When completed abnormally : This device is turned ON by the END
Setting data
: Normal completion
instruction completion can be confirmed using the complete
instruction is completed, and turned OFF by the next END
instruction is completed.
: Kept unchanged at OFF.
processing of the scan for which
ZP.TEACH
turned OFF by the next END processing
(same ON/OFF operation as complete
device).
14 - 13
MELSEC-Q
Setting side
Setting range
( 1)
System
0, 1
User
1 to 600
User
instruction is completed, and