Details of areas
Parameter area
Area where parameters, such as positioning parameters and OPR parameters,
required for positioning control are set and stored.
(Set the items indicated with Pr.1 to Pr.57 , Pr.70 , and Pr.150 for each axis.)
Monitor data area
Area where positioning system or QD75 operation state is stored.
(Set the items indicated with Md.1 to Md.48 , Md.50 to Md.52
1: Md.50 to Md.52 are for the QD75P N/QD75D N only.
Control data area
Area where data for operating and controlling positioning system is set and
stored. (Set the items indicated with Cd.1 to Cd.42 .)
Positioning data area (No.1 to 600)
Area where positioning data No.1 to 600 is set and stored.
(Set the items indicated with Da.1 to Da.10 and Da.27 to Da.29 for each
positioning data.)
Block start data area (No.7000 to 7004)
Area where information required only when carrying out block No. 7000 to 7004
high-level positioning is set and stored. (Set the items indicated with Da.11 to
Da.19 .)
PLC CPU memo area
Area where condition judgment values required for special positioning, etc., are
set and stored.