MAJOR POSITIONING CONTROL
(4) When either of four axes exceeds the speed limit, that axis is controlled with
the speed limit value. The speeds of the other axes are limited at the ratios of
" Da.8 Command speed".
(Examples)
Setting item
Speed limit
Pr.8
value
Command
Da.8
speed
With the settings shown above, the operation speed in speed control is as
follows.
Axis 1: 4000.00 mm/min (Speed is limited by Pr.8 ).
Axis 2: 3000.00 mm/min (Speed is limited at ratios in axes 1, 2, 3 and 4
Axis 3: 2000.00 mm/min (Speed is limited at ratios in axes 1, 2, 3 and 4
Axis 4: 750.00 mm/min (Speed is limited at ratios in axes 1, 2, 3 and 4
Note: Operation runs at speed 1 when a reference axis speed is less than 1 as
a result of speed limit.
In addition, when a bias speed is set, it will be the minimum speed.
(5) An error "No command speed" (error code: 503) will occur if a current speed
(-1) is set in " Da.8 Command speed".
(6) The software stroke limit check is not carried out when the control unit is set to
"degree".
Axis
Axis 1
setting
4000.00mm/
5000.00mm/
min
8000.00mm/
6000.00mm/
min
command speeds).
command speeds).
command speeds).
9 - 104
MELSEC-Q
Axis 2
Axis 3
setting
setting
6000.00mm/
min
min
4000.00mm/
min
min
Axis 4
setting
8000.00mm/
min
1500.00mm/
min