Mitsubishi Electric QD75P1N User Manual page 710

Type qd75p/qd75d positioning module
Table of Contents

Advertisement

15
TROUBLESHOOTING
Classification
Warning
of warnings
code
Speed change
300
during deceleration
JOG
JOG speed limit
301
value
Outside manual
Manual pulse
pulse generator
401
generator
input magnification
range
Warning name
The speed change request is issued
during deceleration stop with JOG
start signal OFF.
• The JOG speed exceeds the JOG
speed limit value at the JOG start.
• The new speed value exceeds the
JOG speed limit value when the
speed is changed during operation.
The manual pulse generator 1 pulse
input magnification is set as follows.
• 0 or 1001 or higher
(QD75P N/QD75D N)
• 0 or 101 or higher
(QD75P /QD75D )
Warning
The speed change is not carried out.
• When the speed exceeds the JOG
• While the speed is limited by the
• When input magnification is set at
• When input magnification is set at
• When input magnification is set at 0:
15 - 44
MELSEC-Q
Operation status at warning
occurrence
speed limit, the JOG operation is
carried out with the JOG speed limit
value.
JOG speed limit value, the "Speed
limiting flag" is turned ON.
1001 or higher: Re-set to 1000.
(QD75P N/QD75D N)
101 or higher: Re-set to 100.
(QD75P /QD75D )
Re-set to 1.

Hide quick links: