12
CONTROL SUB FUNCTIONS
(3) Since the upper/lower limit values of the positioning address calculated are
outside of the range of Condition 2, use the positioning address within the
positioning range of Condition 2 (-214748364.8(m) to 214748364.7(m)).
-241591910.4
-214748364.8
Setting disallowed
2. Concept for the unit of degree
The positioning address is within the range 0 to 359.99999 at the position
to which a machine OPR was made.
When the OP position is not 0, the range is also 0 to 359.99999.
For positioning in the same direction, control from maximum to minimum
(for address increase: 359.99999 to 0/for address decrease: 0 to
359.99999) cannot be exercised. (See below)
359.99999
0
Unusable in absolute position detection
system.
Current value cannot be restored
properly at power supply on or resetting
When positioning is to be used in the absolute position detection system,
set the upper/lower limit values of the software stroke limit within the range
0 to 359.99999.
OP
0
Usable range in absolute
position detection system
OP
359.99999
0
Usable range in absolute position detection system
(
~
0
12 - 72
214748364.7
Setting disallowed
Unusable in absolute position
detection system.
Current value cannot be restored
properly at power-on or reset.
)
359.99999
MELSEC-Q
Unit: m
241591909.5