Mitsubishi Electric QD75P1N User Manual page 682

Type qd75p/qd75d positioning module
Table of Contents

Advertisement

15
TROUBLESHOOTING
Classification
Error
of errors
code
Illegal condition data
500
No.
Positioning
operation
Error before
501
simultaneous start
502
Illegal data No.
Positioning
operation
503
No command speed
Error name
The condition data No. is outside the
setting range when a block using the
condition data is started by a special
starting (conditional start, wait start,
simultaneous start, FOR (condition)).
(1
Condition data No.
<When blocks are started
simultaneously>
• The partner axis for simultaneous
start is BUSY.
<When multiple axes are started and
controlled simultaneously>
• The partner axis for simultaneous
start is BUSY.
• The "Simultaneous start axis start
data No." of the start axis is 0 or is
outside the setting range.
• The "Simultaneous start axis start
data No." of those axes other than
the start axis is outside the setting
range.
• The positioning data No. tried to be
executed is outside the ranges of 1
to 600, 7000 to 7004, and 9001 to
9004.
• The designation of a JUMP
destination is executed currently.
• The designation of a JUMP
destination is outside the ranges of
1 to 600.
• At the start of positioning, a current
speed (–1) is set for the command
speed of the positioning data to be
initially executed.
• The current speed is set by speed
control.
• The current speed is set for speed-
position switching control or
position-speed switching control.
Error
The operation is terminated.
10)
At start: The system will not operate.
During operation:
The positioning data is not executed.
At the start of positioning, operation
15 - 16
MELSEC-Q
Operation status at error occurrence
The system stops
immediately.
does not start.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents