Mitsubishi Electric QD75P1N User Manual page 451

Type qd75p/qd75d positioning module
Table of Contents

Advertisement

9
MAJOR POSITIONING CONTROL
Setting item
Da.1
Operation pattern
Da.2
Control system
Acceleration time
Da.3
No.
Deceleration time
Da.4
No.
Axis to be
Da.5
interpolated
Positioning address/
Da.6
movement amount
Da.7
Arc address
Da.8
Command speed
Da.9
Dwell time
Da.10 M code
Refer to Section 5.3 "List of positioning data" for information on the setting details.
Positioning data setting examples
The following table shows setting examples when "position-speed switching
control (forward run: position/speed)" is set in positioning data No. 1 of axis 1.
Setting example
Set "Positioning complete" assuming the next positioning data will not
Positioning
be executed. ("Continuous positioning control" and "Continuous path
complete
control" cannot be set in "position/speed changeover control".)
Forward run:
Set position-speed switching control.
position/speed
Designate the value set in " Pr.25 Acceleration time 1" as the
1
acceleration time at start.
Designate the value set in " Pr.10 Deceleration time 0" as the
0
deceleration time at deceleration.
Setting not required. (Setting value is ignored.)
Set the movement amount at the time of position control before the
switching to speed control. (Assuming that the " Pr.1 Unit setting" is
10000.0
m
set to "mm".)
Setting not required. (Setting value is ignored.)
6000.00mm/min Set the speed to be controlled.
Set the time the machine dwells after the positioning stop (pulse
output stop) by position control to the output of the positioning
500ms
complete signal. If the machine is stopped by speed control, the
setting value will be ignored.
Set this when other sub operation commands are issued in
10
combination with the No. 1 positioning data.
Setting details
9 - 129
MELSEC-Q