Mitsubishi Electric QD75P1N User Manual page 450

Type qd75p/qd75d positioning module
Table of Contents

Advertisement

9
MAJOR POSITIONING CONTROL
POINTS
The machine recognizes the presence of a command speed change request when the data is
written to " Cd.25 Position-speed switching control speed change register" with the sequence
program.
The new command speed is validated after execution of the position-speed switching control before
the input of the position-speed switching signal.
The command speed change can be enabled/disabled with the interlock function in speed control
using the "position-speed switching latch flag" ( Md.31 Status: b5) of the axis monitor area.
Restrictions
(1) The axis error "Continuous path control not possible" (error code: 516) will
occur and the operation cannot start if "continuous positioning control" or
"continuous path control" is set in " Da.1 Operation pattern".
(2) "Position-speed switching control" cannot be set in " Da.2 Control system"
of the positioning data when "continuous path control" has been set in
" Da.1 Operation pattern" of the immediately prior positioning data. (For
example, if the operation pattern of positioning data No. 1 is "continuous path
control", "position-speed switching control" cannot be set in positioning data
No. 2.) The axis error "Continuous path control not possible" (error code: 516)
will occur and the machine will carry out a deceleration stop if this type of
setting is carried out.
(3) The software stroke limit range is only checked during speed control if the "1:
Update current feed value" is set in " Pr.21 Current feed value during speed
control".
The software stroke limit range is not checked when the control unit is set to
"degree".
(4) The error "Software stroke limit+" or "Software stroke limit-" (error code: 507 or
508) will occur and the operation cannot start if the start point address or end
point address for position control exceeds the software stroke limit range.
(5) Deceleration stop will be carried out if the position-speed switching signal is
not input before the machine is moved by a specified movement amount.
When the position-speed switching signal is input during automatic
deceleration by positioning control, acceleration is carried out again to the
command speed to continue speed control.
When the position-speed switching signal is input during deceleration to a stop
with the stop signal, the control is switched to the speed control to stop the
machine.
Restart is carried out by speed control using the restart command.
(6) The warning "Speed limit value over" (warning code: 501) will occur and
control is continued by " Pr.8 Speed limit value" if a new speed exceeds
" Pr.8 Speed limit value" at the time of change of the command speed.
(7) If the value set in " Da.6 Positioning address/movement amount" is
negative, the error "Outside address range" (error code: 530) will occur.
9 - 128