Mitsubishi Electric QD75P1N User Manual page 818

Type qd75p/qd75d positioning module
Table of Contents

Advertisement

APPENDICES
Monitor current values such
as the current feed value and
feedrate.
Test each function while
checking current values with
the monitor.
Speed change test
The appropriate speed and acceleration/deceleration time can be checked by
changing speed or acceleration/deceleration time or by performing override to the axis
where the positioning start test, OPR test, or JOG operation test is performed.
(1) Operating procedure
1. Open the "Positioning Test" dialog box.
Display the "Positioning Test" window.
[Tool]
[Intelligent Function Module Tool]
Module]
[Positioning Test]
2. Select the test target axis.
Select the test target axis from the pull-down menu of "Target Axis".
Appendix - 102
MELSEC-Q
[QD75/LD75 Positioning

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents