Figure 13: Mc-Aps Group Protects Against Node Failure - Alcatel-Lucent 7750 Configuration Manual

Service router
Hide thumbs Also See for 7750:
Table of Contents

Advertisement

the protection circuit/router is not enforced by the 7750 SR. Service or network-specific
configuration data is not signalled nor synchronized between the two service routers.
Signalling is provided using the direct connection between the two service routers. A heartbeat
protocol can be used to add robustness to the interaction between the two routers. Signalling
functionality includes support for:
Note that external requests like lockout, force, and manual switches are allowed only on the APS
group having the protection circuit.
The
Figure 13
MDA, IOM or node failure.
7750 SR Interface Configuration Guide
APS group matches between service routers.
Verification that one side is configured as a working circuit and the other side is
configured as the protect circuit. In case of a mismatch, a trap (incompatible neighbor) is
generated.
Change in working circuit status is sent from the working router to keep the protect router
in sync.
Protect router, based on K1/K2 byte data, member circuit status, and external request,
selects the active circuit, and informs the working router to activate or de-activate the
working circuit.
illustrates a Multi-Chassis APS group being used to protect against link, port,
CE

Figure 13: MC-APS Group Protects Against Node Failure

Link 1
mc-aps
group
Link 2
Interface Configuration
7750 SR A
mc-aps Signaling Link
7750 SR B
OSSG657