Lane Tx Bias Current (mA)
Lane Rx Optical Pwr (avg dBm)
-------------------------------------------------------------------------------
Lane ID Temp(C)/Alm
-------------------------------------------------------------------------------
1
2
3
4
===============================================================================
Transceiver Type
Model Number
TX Laser Wavelength: 1294 nm
Number of Lanes
Connector Code
Manufacture date
Serial Number
Part Number
Optical Compliance : 100GBASE-LR4
Link Length support: 10km for SMF
===============================================================================
Transceiver Digital Diagnostic Monitoring (DDM)
===============================================================================
-------------------------------------------------------------------------------
Temperature (C)
Supply Voltage (V)
===============================================================================
===============================================================================
Transceiver Lane Digital Diagnostic Monitoring (DDM)
===============================================================================
-------------------------------------------------------------------------------
Lane Temperature (C)
Lane Tx Bias Current (mA)
Lane Tx Output Power (dBm)
Lane Rx Optical Pwr (avg dBm)
-------------------------------------------------------------------------------
Lane ID Temp(C)/Alm
-------------------------------------------------------------------------------
1
2
3
4
===============================================================================
The transceiver is programmed with warning and alarm thresholds for low and high conditions
that can generate system events. These thresholds are programmed by the transceiver
manufacturer.
There are no CLI commands required for DDM operations, however, the show>port port-id
detail command displays DDM information in the Transceiver Digital Diagnostics Monitoring
output section.
DDM information is populated into the router's MIBs, so the DDM data can be retrieved by
Network Management using SNMP. Also, RMON threshold monitoring can be configured for the
7750 SR Interface Configuration Guide
Tx Bias(mA)/Alm
-
43.5
-
46.7
-
37.3
-
42.0
: CFP
: 3HE04821ABAA01
: 4
: LC
: 2011/02/11
: C22CQYR
: FTLC1181RDNL-A5
Value High Alarm
+48.2
3.24
High Alarm
Tx Bias(mA)/Alm
+47.6
59.2
+43.1
64.2
+47.7
56.2
+51.1
60.1
78.0
75.0
2.30
2.00
Tx Pwr(dBm)/Alm
-
-
-
-
ALU
IPUIBHJDAA
Diag Capable
Vendor OUI
Media
High Warn
+70.0
+68.0
3.46
3.43
High Warn
+55.0
+53.0
120.0
115.0
4.50
4.00
4.50
4.00
Tx Pwr(dBm)/Alm
0.30
0.27
0.38
0.46
Interface Configuration
25.0
20.0
-11.02
-13.01
Rx Pwr(dBm)/Alm
0.42
-0.38
0.55
-0.52
: yes
: 00:90:65
: Ethernet
Low Warn
Low Alarm
+2.0
+0.0
3.17
3.13
Low Warn
Low Alarm
+27.0
+25.0
35.0
30.0
-3.80
-4.30
-13.00
-16.00
Rx Pwr(dBm)/Alm
-10.67
-10.31
-10.58
-10.37
Page 33