Interfaces
cpr-window-size
Syntax
cpr-window-size window-size
Context
config>port>dwdm>coherent
Description
This command configure the window size used for carrier phase recovery.
Default
32
Parameters
window-size — Indicates the number of symbols used for carrier phase recovery algorithm of the receiver.
When this parameter is changed, the link will bounce because the receiver needs to be reconfigured.
Values
wavetracker
Syntax
wavetracker
Context
config>port>dwdm
Description
This command validates whether or not the port supports Wavetracker.
Default
None
power-control
Syntax
[no] power-control
Context
config>port>dwdm>wavetracker>power-control
Description
This command specifies whether the power control loop should be turned on to actively control the laser's
launch power to the specified target power. When power-control is disabled, the launch power is set to the
laser's maximum achievable power.
Default
no power-control
Parameters
no power-control — Laser output power is set to maximum.
power-control — Actively control the laser's output power to achieve the target power.
target-power
Syntax
target-power dBm
Context
config>port>dwdm>wavetracker>power-control
Description
This command specifies launch power in dBm for the DWDM Wavetracker-enabled interface.
Default
-20.00 dBm