Ports
Signalling is provided using the direct connection between the two service routers. A heartbeat
protocol can be used to add robustness to the interaction between the two routers. Signalling
functionality includes support for:
Note that external requests like lockout, force, and manual switches are allowed only on the APS
group having the protection circuit.
The following figure illustrates a Multi-Chassis APS group being used to protect against link, port,
MDA, IOM or node failure.
Page 66
APS group matches between service routers.
Verification that one side is configured as a working circuit and the other side is
configured as the protect circuit. In case of a mismatch, a trap (incompatible neighbor) is
generated.
Change in working circuit status is sent from the working router to keep the protect router
in sync.
Protect router, based on K1/K2 byte data, member circuit status, and external request,
selects the active circuit, and informs the working router to activate or de-activate the
working circuit.