report-alarms
Syntax
[no] report-alarms [ild] [tmp] [mth] [mtl] [los] [lop] [com]
Context
config>port>dwdm>amplifier
Description
This command allows users to enable/disable the optical amplifier alarms for the port.
Default
All alarms are enabled
Parameters
ild — Reports amplifier pump over-current faults.
tmp — Reports pump temperature faults.
mth — Reports module case temperature high faults.
mtl — Reports module case temperature low faults.
los — Reports loss of signal faults.
lop — Reports loss of optical power faults.
com — Reports module communication failure faults.
channel
Syntax
channel channel
Context
config>port>dwdm
config>port>dwdm>tdcm
config>port>dwdm>coherent
Description
This command configures the Dense Wavelength Division Multiplexing (DWDM) ITU channel at which a
tunable MDA optical interface will be configured to operate. It is expressed in a form that is derived from
the laser's operational frequency. For example 193.40 THz corresponds to DWDM ITU channel 34 in the
100 GHz grid and 193.45 THz corresponds to DWDM ITU channel 345 in the 50 GHz grid.Provisioning
rules:The provisioned MDA type must have DWDM tunable optics (m1-10gb-dwdm-tun)
Parameters
channel — Specifies the channel.
Values
7750 SR Interface Configuration Guide
The 'dwdm channel' must set to a non zero value before the port is set to 'no shutdown'
The port must be 'shutdown' before changing the dwdm channel.
The port must be a physical port to set the dwdm channel
0, 17-61, 175-605]
where:
17-61 is used for 100GHz channels
Interface Configuration
Page 333