Editing voltage bias values

Use the following keys to edit voltage bias values:
• SRC1 or SRC2: selects the channel 1 (Src1) or channel 2 (Src2) source display field on
the lower line for editing. A blinking cursor will appear in the field to be edited. If no
key is pressed within a few seconds, the edit mode will be cancelled automatically.
• EDIT
• EDIT
these keys will automatically enable the source edit mode.
• RANGE
• Numeric keys (0-9) allow you to directly enter source values.
• EXIT exits the edit mode without waiting for the time-out period.
The basic procedure for editing source values is outlined below. See
measurement procedure,"
1. Press the SRC1 or SRC2 key so the blinking cursor is in either the channel 1 (Src1) or
channel 2 (Src2) source display field to be edited.
2. If desired, use the RANGE
lowest range possible for best accuracy.)
3. To simply increment or decrement the displayed source value, use the EDIT
keys to place the blinking cursor on the digit to be changed, then increment or decre-
ment the value with the EDIT
immediately; you need not press ENTER to complete the process.
4. To enter the source value directly, simply key in the desired value with the numeric
keys while the cursor is blinking. Again, the source value will be updated immediately.
Configuration menus
There are a number of configuration menus that can be accessed by pressing the CONFIG
key followed by the appropriate function or mode key. For example, you can configure the
measurement functions by pressing CONFIG then MSR1 (channel 1) or MSR2 (channel
2). Configuration menus, which are summarized in
available for the following operating modes:
• Measurement functions (MSR1, MSR2, RATIO, DELTA):
• Voltage source (SRC1 and SRC2):
• REL, FILTER, and RANGE:
• LIMIT:
• TRIG:
• SWEEP, DIGITS, SPEED, and STORE:
• ON/OFF OUTPUT and DISPLAY TOGGLE:
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com
and
places the display cursor on the display digit to be changed.
or
increments or decrements the source value. Note that pressing either of
or
selects the voltage bias source range (10V or 100V).
for more details.
and
Table
Table
1-8.
Table
1-9.
Model 2500 and 2502 User's Manual
keys to select the desired source range. (Use the
and
keys. Note that the source value will be updated
Table 1-5
Table
1-6.
1-7.
Table
1-10.
Table
1-11.
Section
3,
"Basic
and
through
Table
1-11, are
Table
1-5.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2502

Table of Contents