Setting Independent Key Transition Dme Wipe Modifiers - Sony MVS-8000 User Manual

Multi format switcher system
Hide thumbs Also See for MVS-8000:
Table of Contents

Advertisement

1
2
3
Setting Independent Key Transition DME Wipe
Modifiers
You can set the pattern position and size for an independent key transition
DME wipe.
For introductory information, see "Positioner" (page 75) and "Size" (page
75).
Setting the DME wipe position (Positioner)
When one of the pattern numbers 1031, 1201 to 1204, 1251, and 2652 is
selected, use the following procedure.
1
2
410
DME Wipe Settings for Independent Key Transitions
In the <Pattern Select> group of the Key1 DME Wipe Adjust menu, press
[1ch].
The Pattern Select menu for one-channel mode appears.
Select the desired DME wipe pattern group with one of the following
buttons.
Slide/Squeeze: slide and squeeze
Split/Door: split and door
Frame I/O: frame in/out
User Program: user programmable DME
For details of DME wipe patterns, see "Types of DME Wipe Pattern"
(page 68) and the appendix "DME Wipe Pattern List" (Volume 2).
The patterns from the selected pattern group appear on the screen.
Press the button to select the desired pattern.
In the <Position> group of the Key1 DME Wipe Adjust menu, press
[Position], turning it on.
Set the following parameters.
Knob
Parameter
Adjustment
1
H
Horizontal position
2
V
Vertical position
Setting values
–200.00 to +200.00
–200.00 to +200.00