2
3

Display of the Key Output Status and Key Priority

You can check whether keys are currently output, and the key priority setting,
using the key status display in the transition control block of the M/E or PGM/
PST bank.
The display is above the next transition selection buttons [KEY1] to [KEY4]
([DSK1] to [DSK4] buttons in the PGM/PST bank).
Display of the key output status
When a key is included in the output from the M/E or PGM/PST bank, the
corresponding ON indicator lights.
Key priority display
The key priority is indicated by numerals 1 to 4 lighting.
The topmost key as seen on the program monitor is priority 1, and the keys
underneath are numbered 2, 3, 4 away from the viewer (see page 291).
To display the key priority for after the transition, press the [KEY PRIOR]
button in the transition control block, turning it on. For keys for which the
priority after the transition is different from the current priority, the
corresponding numerals 1 to 4 flash. For a key with the same priority, the
indication remains on.
Example key status display given when the [KEY PRIOR] button is pressed:
• Current key priority: 1, 2, 3, 4
• Key priority after the transition: 3, 2, 1, 4
• Indicators: 1, 3 (flashing), 2, 1 (flashing), 3, 4
292
Key Priority Setting
The Next Key Priority menu appears.
For each of <Priority1>, <Priority2>, <Priority3>, and <Priority4>, select
a key, to determine the key priority sequence.
For details of the key priority sequence, see the figure shown for step 2 in
the previous item (see page 291).
The keys appear in the set order on the preview monitor.
Execute the transition.
The keys are rearranged in the set order on the program monitor.