5 Block USER INTERFACE
28
5.2

Group MAIN LINE

5.2.1 Function group: CONFIGURATION

Þ
USER INTERFACE
C
USER INTERFACE
A = main line, B = additional line, C = information line
ASSIGN
Use this function to define the display value assigned to the main line (the top
(2200)
line of the local display) during normal measuring operation.
Options:
OFF
VOLUME FLOW CH1
VOLUME FLOW CH2
CALCULATED VOLUME FLOW
VOLUME FLOW % CH1
VOLUME FLOW % CH2
CALCULATED VOLUME FLOW %
SOUND VELOCITY CH1
SOUND VELOCITY CH2
SOUND VELOCITY AVERAGE
SIGNAL STRENGTH CH1
SIGNAL STRENGTH CH2
FLOW VELOCITY CH1
FLOW VELOCITY CH2
FLOW VELOCITY AVERAGE
TOTALIZER 1
TOTALIZER 2
TOTALIZER 3
AI 1 - OUT VALUE
AI 2 - OUT VALUE
AI 3 - OUT VALUE
AI 4 - OUT VALUE
AI 5 - OUT VALUE
AI 6 - OUT VALUE
AI 7 - OUT VALUE
AI 8 - OUT VALUE
PID - IN VALUE (controlled variable)
PID - CAS IN VALUE (remote setpoint value)
PID - OUT VALUE (manipulated variable)
Factory setting:
VOLUME FLOW CH1

If a channel is not visible, it does not appear in the options. The channels can
be displayed or hidden by means of the MEASUREMENT (6880) function.
PROline Prosonic Flow 93 FOUNDATION Fieldbus
CONTROL
CAA
ß
MAIN LINE
CCA
Function description
MAIN LINE
CONFIGURATION
A
ENDRESS+HAUSER
B
-
+
E
ESC
C
Note!
Þ
CONFIGURATION
Endress+Hauser