3 Transducer Blocks (transmission blocks)
100
3
Transducer Blocks (transmission blocks)
3.1
Overview
PROline Prosonic Flow 93 FOUNDATION Fieldbus's Transducer Blocks contain all the
measuring and device-specific parameters of the flowmeter. The settings directly
connected with flow measurement or the application are made here. They form the
interface between sensor-specific measured value preprocessing and the Analog Input
function blocks required for automation.
The Transducer Blocks allow you to influence the input and output values of the function
blocks. The parameters of a Transducer Block include information on the sensor type,
sensor configuration, physical units, calibration, damping, diagnosis, etc. as well as the
device-specific parameters.
The device-specific parameters and functions of PROline Prosonic Flow 93
FOUNDATION Fieldbus are divided among several Transducer Blocks which cover
different tasks. The Figure 2 on Page 101 shows the internal structure of the various
Transducer Blocks:
TRANSDUCER_CH1 (flow channel 1) / base index 1200:
All flow-specific parameters and functions, (such as adjustment functions, sensor data
etc.), for the first channel are located in this block → Page 109.
TRANSDUCER_CH2 (flow channel 2) / base index 1300:
All flow-specific parameters and functions, (such as adjustment functions, sensor data
etc.), for the second channel are located in this block → Page 109.
TRANSDUCER_DISP (display) / base index 1500:
All parameters for configuring the local display are located in this block → Page 129.
TRANSDUCER_TOT (totalizer) / base index 1550:
All parameters for configuring the totalizers are located in this block → Page 148.
TRANSDUCER_DIAG (diagnosis) / base index 1600:
All parameters for system diagnosis, (such as current system status etc.), are located
in this block → Page 156.
TRANSDUCER_SERV (service) / base index 1650:
All parameters for servicing are located in this block → Page 159.
PROline Prosonic Flow 93 FOUNDATION Fieldbus
Endress+Hauser
Need help?
Do you have a question about the PROline Prosonic Flow 93 and is the answer not in the manual?