Group Totalizer - Endress+Hauser PROFIBUS-PA PROline promass 80 Brief Operating Instructions

Coriolis mass flow measuring system
Hide thumbs Also See for PROFIBUS-PA PROline promass 80:
Table of Contents

Advertisement

PROline Promass 80 PROFIBUS-PA
Endress+Hauser
3.5

Group TOTALIZER

SELECT TOTALIZER
Use this function to select a totalizer.
!
Only one totalizer is available to the ProdType.
Options:
TOTALIZER 1
Factory setting:
TOTALIZER 1
TOTALIZER OUT VALUE Use this function to view the TOTAL value (output measured value)and the
corresponding unit of the totalizer.
OVERFLOW
Use this function to view the overflow for the totalizer aggregated since
measuring commenced.
Total flow quantity is represented by a floating-point number consisting of max.
7 digits. You can use this function to view higher numerical values
(>9,999.999) as overflows. The effective quantity is thus the total of ÜBER-
LAUF plus the value returned by the SUMME function.
Example:
Reading for 2 overflows: 2 10
The value displayed in the function SUMME = 196,845.7 kg
Effective total quantity = 20,196,845.7 kg
User interface:
integer with exponent, including sign and unit, e.g. 2 10
CHANNEL
Use this function to assign a measured variable to the totalizer.
Options:
OFF
MASS FLOW
VOLUME FLOW
Factory setting:
MASS FLOW
UNIT TOTALIZER
Use this function to define the unit for the totalizer measured variable.
Options:
Metric
US
bbl (petrochemicals); bbl (filling tanks)
Imperial
Factory setting:
m
Function description TOTALIZER
Note:
7
kg (= 20,000,000 kg)
3
3
3
cm
; dm
; m
; ml; l; hl; Ml
3
cc; af; ft
(cft); oz f (flo); gal; Mgal; bbl (normal fluids); bbl (beer);
gal; Mgal; bbl (beer); bbl (petrochemicals)
3
3 Operation
7
kg
23

Advertisement

Table of Contents
loading

Table of Contents