Adjustment after Replacement

Magnification

Use an S5S test chart to do the following adjustment.
A: Sub-scan magnification
1.
Place the test chart on the exposure glass and make a copy from one of the feed
stations.
2.
Check the magnification ratio and adjust using the following SP mode if necessary.
SP No.
SP4-008-001
D197/D198/D199/D200/D201/D202
SP Name
Sub Scan Magnification
Adj
4-196
Adjustment Range
±1.0 %
SM