5.18.9 INTERNAL FINISHER D766 – OUTPUT CHECK
6185
[Output Check:NoStplBindFIN]
Transport Motor
6-185-001
Checks the transport motor's movement of non staple finisher. Turn the
motor clockwise at 256 mm/sec.
Shift Motor
6-185-002
Checks the shift motor's movement of non staple finisher.
Junction Solenoid
Motor
6-185-003
Checks the junction solenoid motor's movement of non staple finisher.
Exit Pressure Release
Motor
6-185-004
Checks the exit pressure release motor's movement of non staple finisher.
Stapler Motor
6-185-005
Checks the stapler motor's movement of non staple finisher.
SM
ENG
[0 or 1 / 0 / 1/step]
ENG
[0 or 1 / 0 / 1/step]
ENG
[0 or 1 / 0 / 1/step]
ENG
[0 or 1 / 0 / 1/step]
ENG
[0 or 1 / 0 / 1/step]
5-407
D197/D198/D199/D200/D201/D202
Output Check Table