Ricoh D197 Service Manual page 1049

Hide thumbs Also See for D197:
Table of Contents

Advertisement

SC Tables: SC1xx (Scanning)
SC No.
Level
SC101-02
D
SC No.
Level
SC102-00
D
D197/D198/D199/D200/D201/D202
Error Name/Error Condition/Major Cause/Solution
Lamp Error (LED illumination adjustment)
LED error was detected.
LED defective
IDB (LED driver) defective
Power/signal harness defective
1.
Turn the power off/on.
2.
Perform the following operations:
Reconnect the power/signal harness.
3.
Replace the following parts:
Replace the scanner lamp (LED board).
Replace the SIO board.
Replace the power/signal harness.
Error Name/Error Condition/Major Cause/Solution
LED Illumination Adjustment Error
The white level peak reached the prescribed threshold when the
white plate was scanned after a specified number of
adjustments.
LED defective
IDB (LED driver) defective
SBU defective
IPU defective
Power/signal harness defective
1.
Turn the power off/on.
2.
Reconnect the power/signal harness.
3.
Replace the following parts:
Replace the scanner lamp (LED board).
Replace the lens block (SBU board).
Replace the SIO board.
Replace the IPU board.
Replace the power/signal harness.
6-6