Copy Data Security Unit Type G
3. Attach the ICIB-3 bracket [A] to the IPU (
4. Reassemble the machine.

User Tool Setting

1. Plug in the machine and turn on the main power switch.
2. Go into the User Tools mode, and select System Settings > Administrator Tools > Copy
Data Security Option > "On".
3. Exit User Tools.
4. Check the operation.
The machine will issue an SC165 error if the machine is powered on with the ICIB-3
removed and the "Data Security for Copying" feature set to "ON".
The machine will issue an uncertain SC165 error if ICIB-3 is defective when the
machine is powered on and the "Data Security for Copying" feature is set to "OFF".
When you remove this option from the machine, first set this feature to "OFF" with
the user tool before removing this board. If you forget to do this, "Data Security for
Copying" feature cannot appear in the user tool setting. Also, SC165 will appear
every time the machine is switched on, and the machine cannot be used.
5. Make sure that the machine can recognize the option.
D197/D198/D199/D200/D201/D202
x2; M3 x 6).