Displays the result before the last 6 result of the process control
execution.
History:Last 8
3-012-008
Displays the result before the last 7 result of the process control
execution.
History:Last 9
3-012-009
Displays the result before the last 8 result of the process control
execution.
History:Last 10
3-012-010
Displays the result before the last 9 result of the process control
execution.
*SP3-012 Display result detail
Category
Code Result name
00 or more
00
10 or more
11
Result (Normal)
21
22
23
20 or more:
ID Sensor
24
25
26
SM
*ENG
*ENG
*ENG
Not executed
Succeed
ID Sensor Vsg adjust error
ID Sensor LED Adjust error
ID Sensor Output error
(regular reflect)
ID Sensor output error
(diffusion reflect)
ID Sensor offset Voltage error
(regular reflect)
ID Sensor offset Voltage error
(diffusion reflect)
5-43
SP Mode Tables - SP3000
[0 to 99 / 0 / 1/step]
[0 to 99 / 0 / 1/step]
[0 to 99 / 0 / 1/step]
Description
Factory default setting (SP
default)
-
Out of range from Vsg_reg
= 4.0 ± x.x[V/step]
Ifsg > Max
Vsg_reg < Min (Max)
Vsg_dif < Min(Max)
Voffset_reg > Max
Voffset_dif > Max
D197/D198/D199/D200/D201/D202