5-816-065 Proxy User Name
5-816-066 Proxy Password
5-816-067 CERT:Up State
0
The certification used by RCG-N is set correctly.
The certification request (setAuthKey) for update has been received
1
from the GW URL and certification is presently being updated.
The certification update is completed and the GW URL is being
2
notified of the successful update.
The certification update failed, and the GW URL is being notified of
3
the failed update.
The period of the certification has expired and new request for an
4
update is being sent to the GW URL.
SM
[- / - / -]
This SP sets the HTTP proxy
certification user name.
The length of the name is
*CTL
limited to 31 characters. Any
character beyond the 31st
character is ignored.
This name is customer
information and is not printed in
the SMC report.
[- / - / -]
This SP sets the HTTP proxy
certification password.
The length of the password is
*CTL
limited to 31 characters. Any
character beyond the 31st
character is ignored.
This name is customer
information and is not printed in
the SMC report.
[0 to 255 / 0 / 1/step]
*CTL
Displays the status of the certification
update.