SP Mode Tables - SP1000
1142
[Fusing Jam Detection]
SC Display
1-142-001
Display SC or not when detecting a fusing jam 3 times in a roll.
1152
[Fusing Nip Band Check]
Execute
Measure nip.
1-152-001
The standard specification of this machine is +/-0.8 mm. if the value is out
of range, the fusing unit needs to be replaced.
1153
[Abnormal Noise Confirmation] DFU
1-153-001 Unit: Execute
1-153-002 No Unit: Execute
1-153-003 Operation Line Speed
1-153-004 Operation Time
Heat Center Target
1-153-005
Temp
1-153-006 Heat End Target Temp
1-153-007 Press Target Temp
D197/D198/D199/D200/D201/D202
[0 or 1 / 0 / 1/step]
*ENG
0: OFF
1: ON
ENG
[0 or 1 / 0 / 1/step]
ENG
[0 or 1 / 0 / 1/step]
ENG
[0 or 1 / 0 / 1/step]
[0 to 2 / 0 / 1/step]
0: Std Speed
ENG
1: Mid Speed
2: Low Speed
ENG
[0 to 240 / 60 / 1sec/step]
ENG
[100 to 180 / 130 / 1deg/step]
ENG
[100 to 180 / 130 / 1deg/step]
ENG
[0 to 200 / 0 / 1deg/step]
5-30