SC No.
Level
SC142-00
D
SM
Error Name/Error Condition/Major Cause/Solution
White Level Detection Error
The white level cannot be adjusted to the second target level
within the target during auto gain control.
SBU defective
LED defective
IDB (LED driver) defective
IPU defective
Power/signal harness defective
Scanner drive error
Condensation in scanner unit
Mirrors or lenses dirty or positioned incorrectly
White plate dirty or installed incorrectly
1.
Turn the power off/on.
2.
Perform the following operations:
Reconnect the power/signal harness.
Reattach/clean the mirrors/lenses.
Reattach/clean the white plate.
3.
Replace the following parts:
Replace the lens block (SBU board).
Replace the scanner lamp (LED board).
Replace the IPU board.
Replace the SIO board.
Replace the power/signal harness.
6-9
SC Tables: SC1xx (Scanning)
D197/D198/D199/D200/D201/D202