[AccumImgArea :Disp]
3252
Displays accumulated image area (K).
3-252-001 ImgArea
3260
[Temperature/Humidity: Display]
Temperature
3-260-001
Displays temperature of environment sensor output.
Relative Humidity
3-260-002
Displays relative humidity of environment sensor output.
Absolute Humidity
3-260-003
Displays absolute humidity of environment sensor output.
[ID.Sens :Voffset]
Displays the regular reflection output of ID sensor when the LED of the ID
3310
sensor is off.
Normal condition: Approximately 0.1V or less.
3-310-001 Voffset reg
3310
[ID.Sens :Voffset]
Voffset TM(Front)
Displays the regular reflection output of ID sensor when the LED of the ID
3-310-021
sensor is off.
Normal condition: Approximately 0.1V or less.
SM
*ENG
[0 to 65535 / 0 / 1cm
ENG
[-5.0 to 45.0 / 0.0 / 0.1deg]
ENG
[0.0 to 100.0 / 0.0 / 0.1%RH/step]
[0.00 to 100.00 / 0.00 /
ENG
3
0.01g/m
/step]
*ENG
[0.00 to 5.50 / 0.00 / 0.01V/step]
*ENG
[0.00 to 5.50 / 0.00 / 0.01V/step]