Ricoh D197 Service Manual page 716

Hide thumbs Also See for D197:
Table of Contents

Advertisement

5
Notification that no certification was issued.
6
Notification that GW URL does not exist.
5-816-069 CERT:Up ID
5-816-083 Firm Up Status
Firm Up User
5-816-085
Check
5-816-086 Firmware Size
5-816-087 CERT: Macro Ver.
SM
[- / - / -]
*CTL
The ID of the request for certification.
[0 to 5 / 0 / 1/step]
Displays the status of the firmware update.
0: Farm update reception standby
1: Farm update start schedule standby.
2: User confirmation standby.
*CTL
3: Device farm update preparation is
executing.
4: Device farm update process is executing.
5: Device farm update end process is
executing.
This SP setting determines if the operator can
confirm the previous version of the firmware
before the firmware update execution. If the
*CTL
option to confirm the previous version is
selected, a notification is sent to the system
manager and the firmware update is done
with the firmware files from the URL.
Allows the service technician to confirm the
*CTL
size of the firmware data files during the
firmware update execution.
[- / - / -]
CTL
Displays the macro version of the @Remote
certification. Max. 8digits.
5-141
SP Mode Tables - SP5000-2
D197/D198/D199/D200/D201/D202

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D198D202D200D199D201

Table of Contents