SP Mode Tables - SP1000
1135
[Inrush Control]
Inrush Control
If the heater's surge current flows into the UPS or power circuit breaker,
1-135-001
the power may be cut. Is you set this to "1", the heater's surge current on
startup is controlled, allowing continual use even if the current flows into
the UPS or power circuit breaker.
However, setting this to ON will extend the initialization time by
approximately one second.
1141
[Fusing SC Error Time Info]
SC Number
1-141-001
Display occurring SC.
Htg Roller:Ctr Det1
1-141-101
Display detailed conditions when an SC occurs. Displayed content is
temp.: center: occurred time.
Htg Roller:End Det1
1-141-102
Display detailed conditions when an SC occurs. Displayed content is
temp.: center: occurred time.
Press Roller:Ctr Det1
1-141-103
Display detailed conditions when an SC occurs. Displayed content is
temp.: center: occurred time.
Press Roller:End Det1
1-141-104
Display detailed conditions when an SC occurs. Displayed content is
temp.: edge: occurred time.
D197/D198/D199/D200/D201/D202
[0 or 1 / 0 / 1/step]
*ENG
0: Normal (Default)
1: Inrush Control mode
*ENG
[0 to 99999 / 0 / 1/step]
*ENG
[-5 to 300 / 0 / 1deg/step]
*ENG
[-5 to 300 / 0 / 1deg/step]
*ENG
[-5 to 300 / 0 / 1deg/step]
*ENG
[-5 to 300 / 0 / 1deg/step]