Ricoh D197 Service Manual page 544

Hide thumbs Also See for D197:
Table of Contents

Advertisement

[Stored Reception File User Setting].
[Notify Destination] in [User Tools/Counter] - [Facsimile Features] - [Reception
Settings] - [Folder Transfer Result Report].
Specified folder in [User Tools/Counter] - [Facsimile Features] - [Send Settings] -
[Backup File TX Setting].
[Receiver] in [User Tools/Counter] - [Facsimile Features] - [Reception Settings] -
[Reception File Settings] - [Output Mode Switch Timer].
[Store: Notify Destination] in [User Tools/Counter] - [Facsimile Features] - [Reception
Settings] - [Output Mode Switch Timer].
All the destination information shown on the display.
In the fax settings, address book data is stored with entry IDs, which the system
internally assigns to each data. The entry IDs may be changed due to
re-assigning in backup/restore operations.
4. Make sure that there is no transmission standby file. If any standby file exists, ask the
customer to delete it or complete the transmission.
8.
Turn the main power OFF and unplug the power supply cord.
9.
Push the main power switch ON again to discharge the residual charge.
10. Replace the NV-RAM with a brand-new one.
11. Turn the power ON.
After turning the power ON, SC995 will be displayed except for machines that have a
smart operation panel.
For machines that have a smart operation panel, SC673 will occur and SC995 might
be internally issued after turning the power ON.
After turning the power ON, SC870 will occur and the address book data will be
cleared.
<Additional procedure only for machines that have the Smart Operation Panel
installed>
SC673 will be displayed at start-up, but this is normal behavior. This is because the
controller and the smart operation panel cannot communicate with each other due to
changing the SP settings for the operation panel.
1. Change the SP settings for the operation panel.
SP5-748-101: (OpePanel Setting: Op Type Action Setting): Change bit 0 from "0" to
"1".
SP5-748-201: (OpePanel Setting: Cheetah Panel Connect Setting): Change the
value from "0" to "1".
SM
4-171
D197/D198/D199/D200/D201/D202
PCBs and Other Items