3031
[TD Sens Init OK?]
K
3-031-001
Displays execution result of TD sensor initial setting.
3050
[Force Tnr Supply :Exe]
Execute
3-050-001
Executes the forced toner supply (K).
Supply Quantity
3-050-021
Sets the supply quantity (K) for the forced toner supply by [wt%] step.
A larger value increases the toner supply amount.
[T Sensor: Check]
3072
Executes testing mode to test TD sensor's output (Vt) without starting up
the engine.
3-072-001 Execute Check
[T Sensor Measurement Value:]
Displays TD sensor output voltage (mu count) when SP3-072-001 is
3073
executed.
Normal value is approximately 6000 to 6200.
3-073-001 mu count
SM
[0 to 9 / 0 / 1/step]
0: No execution
1: Success
ENG
2: No developer error
3: Out of target range
9: Forced termination
ENG
[Execute]
*ENG
[0 to 5/ 0.5 / 0.1/wt%]
ENG
[Execute]
*ENG
[0 to 65535 / 0 / 1/step]
5-45
D197/D198/D199/D200/D201/D202
SP Mode Tables - SP3000