5 Calibration, M2000
5.3.8 Resetting of Levelmeter 2000 and sensor
5.3.8 Resetting of Levelmeter 2000 and sensor
General
The equipment must first be reset before calibrating each axis.
This section details how to reset the Levelmeter 2000 and make the one sensor ready for
calibration.
Levelmeter 2000
The Levelmeter 2000 is shown for reference below:
C
xx0200000083
A
B
C
Sensor mounted
When using the sensor as a reference sensor it is fitted to the sensor fixture, together with a
on fixture
sensor plate, as shown below.
See the section Positions and directions of sensor on page 106 for actual positioning and
orientation of the fixture and the sensor, since the direction of the sensor differs depending on
which axis is calibrated.
Y
xx0100000207
124
-
0 0 0 0 0 0 0 0 0 0 0 0
+
° oo
A°o o
mRAD
mm/m
DEG
Port/Sensor
"1/12"
"1/10"
"/REL"
mm/REL
GON
A
5 0
B AT T
L E V E L M E T E R 2 0 0 0
+
O N /M O D E
Z E R O S E LE C T
-
E N T E R
S E N D /E S C
H O L D
W Y L E R
A
B
O U T
Measuring unit
Selection pointer
Sensor connection
X
C
B
A
B
A
3HAC021111-001 Revision: B