Step
3HAC021111-001 Revision: B
Action
6.
Fit the calibration sensor on the turning disk fixture.
Carefully tighten the securing screws with approxi-
mately same tightening torque that used at the refer-
ence plane.
7.
Manually run axis 5 in with the joystick to the correct
position as indicated by the levelmeter.
Tip!
Reduce the jogging velocity in order to easily position
the axis as close to zero as possible!
8.
Update only axis 5.
9.
Remove the sensor.
10.
Check the calibration according to section Post cali-
bration procedure on page 129 or continue with cali-
bration of next axis.
11.
Refit the cover plate on the reference surface at the
base if no further calibration is performed.
5 Calibration, M2000
5.3.5 Calibration, axis 5
Illustration
Shown in the section Posi-
tions and directions of sen-
sor on page 106!
Correct measurement on
the levelmeter:
0 ±0.80 mm/m
Detailed in section Fine cali-
bration procedure on TPU
on page 122.