6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)
6.3.5.26

The "Agent Time Config" WBM menu

Agent Time Client Configuration
This dialog is used to configure the time protocols.
Figure 6-31
Current system time
Either the time since the last restart or the current time is displayed here.
If the time is received from a "non-time server", the text "not synchronized" is displayed.
Enable time client
The time function can be enabled and disabled here.
Time client type
You can choose from four different protocol types here:
● SNTP Poll
● SNTP Listen
SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19
Agent Time Client Configuration dialog
If you choose this protocol type, you have to define further settings:
Time zone offset, Time server, Init poll interval, Poll interval.
In this mode, you can also select an offset to the time received from the server. Other
settings are not possible.