NIC (NIC Only)
iSCSI (NIC + iSCSI)
FCoE (NIC + FCoE)
Note:
1
WWN is available only when Personality is set to FCoE.
.
(a) Functions of Optional Physical MAC address assignment and of
management module MAC address view when MultiChannel Support is
enabled are supported only by the firmware versions shown in the following
table.
- Management module
A0125 or later
- Server blade firmware
For CB 520H A1/B1:Integrated FW 01-44 or later
For CB 520A A1:Integrated FW 02-16 or later
For details about MultiChannel Support configuration, see the
OneCommandManager Guide.
(b) The following restrictions are on Optional Physical MAC address
assignment to the iSCSI port when Personality is set to iSCSI and
MultiChannel Support is disabled.
- CB 520H A1/B1, CB 520A A1, CB 540A A1/B1 server blades do not support
it.
- CB 520H B2 server blade supports it with firmware versions shown in the
following table.
When Optional Physical MAC address is selected with a not-supported
firmware version in operation and then a supported firmware version is
applied, the iSCSI port is changed to Optional Physical MAC address. Thus,
when using a not-supported firmware version, make sure to select Default
Physical MAC address for operation.
- Management module
A0165 or later
- Server blade firmware
Integrated FW 04-11 or later
(c) The following restrictions are on Optional Physical MAC address
assignment to the FCoE port and management module MAC address view.
2-56
Hitachi Compute Blade 500 Series Management Module Setup Guide
Personality
setting value
Functional detail
MultiChannel Support setting value
Disabled
MAC
WWN
No restriction
-
(b)
-
(c)
(d)
Enabled
MAC
WWN
(a)
1
(a)
1
(a)/(c)
(d)
1
-
1
-

Hide quick links: