Confirmation for OS serial port setting
The OS console is connected COM2 port of the server blade. The connecting
procedure is different depend on the type of server blade OS.
The following table describes the COM2 port configuration of the OS.
Windows
Port
Baud rate
Data
Parity
Stop
Flow control
Recommended terminal type
Note: Windows Special Administration Console (SAC) cannot be used the OS
console.

Red Hat Enterprise Linux

The following table describes the OS parameter configuration.
/boot/grub/grub.conf
configuration
/etc/inittab
configuration
/etc/sysconfig/kudzu
configuration
/etc/security
configuration
Tip:
You need to install the Linux login mode using "Text mode".
2-46
Hitachi Compute Blade 500 Series Management Module Setup Guide
Table 2-55 COM2 port configurations
Item
Table 2-56 Parameter configurations
Item
Adding console=tty0
console=ttyS1,115200 at the end of each
kernel line.
Adding co:2345:respawn:/sbin/agetty
115200 ttyS0 vt100 at the last line.
Perform init q (telinit –q) after adding
the above configuration.
Changing to SAFE=yes.
Adding ttyS0.
Functional detail
COM2
115200
8 bit
N/A
1 bit
N/A
VT100
Description
Description
Remarks
-
This setting is not
needed for Linux 6.2
or later.
This setting is not
needed for Linux 6.2
or later.
-

Hide quick links: