Hitachi COMPUTE BLADE 500 SERIES Management Module Setup Manual page 140

Hide thumbs Also See for COMPUTE BLADE 500 SERIES:
Table of Contents

Advertisement

7
Enter IP Address, Subnet Mask, Default Gateway, VNIC System No, and
.
Time Zone. It is recommended that LP ID should be also entered although
it is optional.
Note:
2-116
Hitachi Compute Blade 500 Series Management Module Setup Guide
Do not set the IP address set for management module or BMC for LP
IP address. If the IP address for management module is set for LP IP
address, web console would not start. In addition, if the IP address for
BMC is set for LP IP address, remote console would not start.
VNIC System No. is used for creating MAC address to prevent the
duplication of MAC address between shared NIC and virtual NIC. Set a
unique number for all LPAR manager system, including Compute
Blade Series.
[Management module firmware version A0135 or earlier]
Specify from 1 to 128.
[Management module firmware version A0145 or later]
Specify 1 or larger. The maximum value depends on the LP firmware
version.
[No LPAR manager firmware assigned to the server blade]
Specify from 1 to 128.
[LPAR manager firmware version 01-5X or earlier]
Set the IP addresses and default gateways for LPAR manager and the
management module so that they are in the same network.
[LPAR manager firmware version 01-60 or later]
Set the IP address and default gateway for LPAR manager so that
they are in the same network.
Functional detail

Hide quick links:

Advertisement

Table of Contents
loading