Displaying management module firmware
Updating management module firmware
Table 2-159 LCD touch console operation
Item
Displaying management module
firmware
Updating management module
firmware
Tip:
When you execute update using HCSM, the management module
firmware version needs to be A0150 or later.
When executing update using HCSM, see the Hitachi Compute Systems
Manager Software User Guide.
(1) Obtaining the latest versions of Management module firmware/
Dictionary/Equipment parameter
Contact your reseller for where to download the latest management module
firmware, dictionary, and system parameter.
Note:
Do not change the file name. If the file name is changed, the
management module cannot recognize it as a firmware file.
Files for other system units, such as that for CB 2000, cannot be applied.
(2) Checking the current version and management module state:
active or standby
Check that versions of the management module firmware, dictionary, and
equipment parameter, which are obtained in (1), are later than the current
versions.
When a management module firmware is updated, the management module
automatically reboots to disconnect. Check Hot standby status for
management module 0 and 1. Make sure that the active and standby
assignments are the same as those before updating.
1
Click Resources tab.
.
2
Click All Modules > Management Modules.
.
Hitachi Compute Blade 500 Series Management Module Setup Guide
Table 2-158 CLI console command
Hardware maintenance > Management Module
(MM) > Detail display
Hardware maintenance > Management Module
(MM) > Firmware update
Functional detail
Command
show mgmt-module firmware
update mgmt-module firmware
Operation
2-285