You need to configure the following settings when synchronizing the clock
time through the management module.
BMC
Select the BMC time adjustment method to Using NTP servers.
The synchronizing clock time are performed after BMC boot, and then
every 15 minutes.
LPAR manager
From the LPAR manager console, configure the settings so that the clock
time is adjusted through the management module.
The synchronizing clock time are performed after LPAR manager boot,
and then every 15 minutes.
Note: For CB520X B1/B2, BMC time adjustment method is only set to
Synchronize time to the management module using NTP.
Tip:
In the initial settings (the settings at shipping time) of the system unit,
the BMC time setting is set to Synchronize time to the management
module using NTP. We recommend that you do not change the settings.
When synchronizing the clock time with the management module, we
recommend that you synchronize the clock time of management module
with the clock time of NTP server.
For details about the LPAR manager console, see the Hitachi Compute
Blade 500 Series Logical partitioning manager User's Guide.
The following table describes the time control.
Setting time in BMC Resources tab > Modules > All modules > Server blades >
Note:
1
x: One of Server blade 0 – 7.
.
2-10
Hitachi Compute Blade 500 Series Management Module Setup Guide
Figure 2-2 Time synchronization
Table 2-18 Web console operation
Item
Server blade x
Functional detail
Operation
1
> BMC tab