FDD0
[Meaning] Device configuration has problem.
[Action] If you change the device configuration before this message appeared, check if
something wrong is in the configuration. If there is no problem in the configuration,
consult your reseller or maintenance personnel.
FDD1
[Meaning] Device configuration has problem.
[Action] If you change the device configuration before this message appeared, check if
something wrong is in the configuration. If there is no problem in the configuration,
consult your reseller or maintenance personnel.
FDD2
[Meaning] Power of server blade at the part shown in X is inhibited for device
configuration error. The problem may be caused by following reasons:
Construction and setting have problem. (Combination of hardware is invalid/power
shortage)
Working state of maintenance. (Power operation for maintenance module/failure
module)
[Action] Eliminate the course of inhibition. If you cannot find course, consult your
reseller or maintenance personnel.
FDD3
[Meaning] Power supply capacity is insufficient.
[Action] Check if power supply modules are correctly installed. Consult your reseller or
maintenance personnel.
FDD5
[Meaning] The total number of cooling fan modules is insufficient.
[Action] Check if cooling fan modules are correctly installed. Consult your reseller or
maintenance personnel.
FF05
[Meaning] When redundancy of LAN port at the part shown in X is available, the LAN
port has switched to another port.
[Action] No particular action required when only this message appeared, because of
keeping redundancy. If the message ID: FD78 appeared with this message, check if the
specified LAN port is connected.
FF06
[Meaning] The LAN port route is restored from the changed route of message ID: FF05.
[Action] No particular action required.
A-10
Hitachi Compute Blade 500 Series Management Module Setup Guide
ID
Level
WARNING
FAIL
WARNING
FAIL
FAIL
Info
Info
HCSM alert log message
Description
Warning about the system configuration
is detected.
System configuration error is detected.
System power activation is deterred for
system configuration error.(Location:X)
Power supply capacity is insufficient.
The total number of cooling fan modules
is insufficient.
LAN port <X> has switched to another
port.
LAN port <X> has recovered from an
error.
Message