Emulex 8 Gb 2-port Fibre Channel mezzanine card supports Optional
Physical WWN function and Default Physical WWN display function as
following version.
- Management module
A0115 or later
- Server blade firmware
For CB 520H A1/B1:Integrated FW 01-37 or later
For the versions listed in the table below, the following features of the
Emulex 10 Gb onboard CNA (4 ports) on the CB 520X B1 server blade are
supported:
- MAC features
Additional MAC address assignment feature Management module MAC
address display feature
- WWN features
Additional WWN assignment feature Management module WWN display
feature
- Management module
A0220 or later
- Server blade firmware
Integrated FW 06-12 or later
For unsupported firmware, if you selected and were using an additional
MAC address, when supported firmware is applied, the MAC address will
switch to the additional MAC address.
For this reason, if you are using unsupported firmware, you must select
and use the original MAC address.
For unsupported firmware, if you selected and user using an additional
WWN, when supported firmware is applied, the WWN of the FCoE port will
switch to the additional WWN.
For this reason, if you are using unsupported firmware, you must select
and use the original WWN.
If you select Custom for the Personality setting for the Emulex 10 Gb
onboard CNA (4 ports), the additional MAC address assignment and
additional WWN assignment features cannot be used. If you select
Custom, you must select and use the original MAC address and the
original WWN.
Note: Depending on the firmware version and the Personality and
MultiChannel Support settings, the restrictions described in (a) to (d) apply to
the following features of the Emulex 10 Gb CNA/LAN expansion cards and
onboard CNA (2 ports) on the CB 520H A1/B1/B2, CB 520A A1 and CB 540A
A1/B1 models. Make sure to follow those restrictions in operation.
- MAC
Assigns Optional Physical MAC address.
Displays MAC address of the management module.
- WWN
Assigns Optional Physical WWN address.
Displays WWN address of the management module.